Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Information

•DSC Testing
Differential scanning calorimetry (DSC) is a technique in which the difference in the amount of heat required to increase the temperature of a sample and reference is measured as a function of temperature by thermal analysis. According to the regulatory of ASTM F2004-17, DSC can be used for testing the Af temperature of nitinol ingot.

 

•Tensile Testing
Tensile testing per ASTM F2516-18 Standard Test Method for Tension Testing of Nickel-Titanium Superelastic Materials is a must for superelastic Nitinol wires and tubes, by which both mechanical properties and super-elastic performance data can be obtained, recorded and reported.  The tensile tests are programmed and pre-set per above standard.  Most of such tests are done in room with controlled temperature of 22±2°C.

 

•Rotary Bending Fatigue Test
As defined in ASTM E2948-2016a Rotating Bending Fatigue Tests of Solid Round Fine Wire, ZHP Medical Inspection Reporhas established such corresponding testing devices, with adjustable bend radius to achieve specified strain for a given diameter of Nitinol wires and automatically count of the cycle numbers.

 

•Optical Profilometry
As required by precision manufacturing, accurate measurement of dimensions of medical implants and interventional devices is of critical importance to secure the performance.  Currently, we have different optical measurement ways in identifying structures and device features, as well as all the key dimensions in 3D.  The accuracy can be controlled at 0.000* mm level, and the optical measurement can be realized by different lighting such as bottom lighting, top-lighting and tilt-lighting if necessary.  Also imperfection of the material or part can also be identified reasonably.

 

•Weld-adhesion Test
One of the key measures to secure the welding adhesion is to test the welded parts, in either non-destructive or destructive way, especially in the prototyping of welding.  Every new welded procedure has to subject to such evaluation and verification.

 

•Corrosion Resistance Test
As a compulsory requirement, all the implanted metallic devices or parts have to subject to Corrosion Resistance Test per ASTM F2129-19a Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices.  As added service, ZHP Medical Inspection Repor can supply such test on Electro-polished and passivated medical parts.  For Stainless Steel implants, the parts have to go through ASTM A967-17 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts.  Other electro-polished and passivated parts such as Co-Cr parts, Nitinol parts can also be tested with above standard as reference.

 

•Grain-size Measurement
ZHP Medical has the capability of check the average grain-size of parts per ASTM E112-13 Standard Test Methods for Determining Average Grain Size, especially when the parts are subjected to high-temperature heat treatment.  The testing data and photos can be pulled out for traceability.


•Micro-hardness
Most of high-temperature heat treated parts need to be evaluated on the micro-hardness.  At ZHP Medical, our micro-hardness meter can be programmed tested and the data can be both stored and printed.